Tikfollowers

Move out of range klipper bed mesh. Add the following to Z section e.

000 12. Better would be 25. And here still the same behavior…. 28 at the start of the print. General Discussion. After ACCEPTing the Z offset, the beacon response will be measured over the sensing range, and the beacon model constructed. My probe is offset from the head by -40mm on the X and bed width is 235mm. Thingiverse Groups. BED_MESH_CALIBRATE completes successfully. 99 my guess this can be done in the software ( taking the lowest value from the BED_MESH_CALIBRATION). 2022年06月17日 19:37 --浏览 · --点赞 · --评论. bin" to a SD card and. 012500 would be considered normal. 000 0. You could make a mesh of just one side of your bed if you really wanted (note: that would be weird, don't do that). At the beginning of the calibration, I received an error: Move out of The Bed Mesh module may be used to compensate for bed surface irregularities to achieve a better first layer across the entire bed. George January 21, 2023, 1:24pm 2. If your position_max is 240 and your probe's y_offset is -40. 000 -2. cfg is not needed. I changed mesh_min and max to be sane 20,20 / 280,280 and my starting point is now normal, however it keeps trying to take the x out of bounds. Here's my printer. Instead of letting the probe pin touch the print bed, let it touch the nail on your finger. SKIP_MANUAL_PROBE will skip the manual process, and assumes the nozzle is already positioned against the bed. Doing Homing of all axis no errors occur. Ender 6 bed is 250x250 but due to extruder change it is now 220x250. 00 G1 X100 Y100 moves as expected but sets Z at 207. MESH_MAX - See Klipper documentation for BED_MESH_CALIBRATE. Hi, I've just got up and running with Klipper on my Ender3-Pro, but am having a minor issue with mesh leveling using a BLTouch. 00 0. Then error: Move out of range: 2. 599 10. no trigger on probe after full movement完全移动后未触发探针. I got some problem with my Klipper when trying to do a BED_MESH_CALIBRATE Get “Move out of range: 0. I hope this is understandable. 000 5. 0 E15 ; Draw the first line G1 X0. org Bed Mesh - out of range Move out of range: 0. 7, 17. 727 [10402. I edited the Printer G-Code in Cura to just use the START_PRINT and END_PRINT macros in the Klipper printer config. ) tried to move to a location that is beyond the limits An indirect movement correction (e. Mar 26, 2022 · At 0. 560 [15. Also if for whatever reason your parts are not in the center of the build Move out of range: 165. 025mm) then the probe does not have sufficient accuracy for typical bed leveling procedures. (1) Add the following macro to your printer config, this will replace the default BED_MESH_CALIBRATE command. 700” is your X Axis move, so you have the mesh minimum set to 10 and the probe offset is 20. 000] You also may check the maximum values of the bed mesh area. 6 KB) Hi! I always have move out of range on bed mesh calibrate. DarkPhoinix January 21, 2023, 2:02pm 3. 390]". 2 board. 000]” printer. 999 [0. Hope that there is a quick fix for this problem. There are some macros that poke around inside some important parameters. The bed mesh is calculated using the mesh_min and mesh_max. Docking and undocking klicky proble also ok. Bed warms up. 000, the BL-Touch is out of the bed. cable used for the LCD module as follows: 3: Tx, 4: Rx, 9: GND, 10: VCC. 60. BED_MESH_PROFILE SAVE=p1. 000] My current BLTouch block is this: [bltouch] set_output_mode: 5V sensor_pin: ^PC14 control Aug 25, 2020 · It creates a wall of text, and prevents proper evaluation. 000 -1. position_min: -0. mesh_min应该大于y_offset值. 200 375. 000] And I'm told I can't go below that. final nozzle temp is reached. 000 100. 000 63. 000] , always on that same spot. Help appreciated. First layers can be hard to get right. BED_MESH_CALIBRATE. Learn how to find the offsets of your bed leveling device and then create a mesh. 000 50. Dec 6, 2021 · Recv: !! Move out of range: 291. I tried looking it up something to do with the print start gcode? The problem I'm running into is if I do a bed mesh calibration and run a print, I almost always run into it stopping on the first layer with the message: "Move out of range: 181. Advertisement. 0 ; Move to start position G1 X0. Jan 11, 2020 · Pulled the latest updates and noticed the changes in bed_mesh taking into account for probe offsets. 5 . 000] Nov 4, 2018 · When printing, I found a “lens” - in the center the distance from the nozzle to the table coincides, but to the edges it is smaller and the nozzle touches the table. 000] Sometimes it starts when restarting the print often enough, but I guess that is not how it should behave. 313 85. 500 -0. And much more. Is the expectation that I turn off the z-endstop? Or raise the whole bed physically, so the lowest point is not below the z-endstop? The Bed Mesh module may be used to compensate for bed surface irregularities to achieve a better first layer across the entire bed. 2. If this occurs, change your start scripts to move the toolhead to a valid position immediately after homing. I am quite new to klipper and followed a very useful youtube video on the initial calibration. The Bed Mesh module may be used to compensate for bed surface irregularities to achieve a better first layer across the entire bed. as far as your z_offset, when it does and autocalibrate, if you look at the very bottom of your config file, it has a ### or something like that. Try changing the mesh_min values to 30. November 21, 2022. BED_MESH_CALIBRATE ADAPTIVE=1 ADAPTIVE_MARGIN=5. G1 X0 Y0 Z5 F4000. 0 Z0. When I tried to do that, the print head would move to the safe-z-home spot and lower until the BLTouch engaged. g [stepper_z]. Further, should the printer then be commanded to a position of X50 Jul 13, 2022 · You have to calculate the offset of the probe into the mesh boundaries. It has a Briss Fang installed hence the larger than normal probe offsets for the CR Touch. 粉丝:316 文章:7. This is extremely frustrating and should not work like this. Output message: Move out of range: -6. 7 so the printer wants to send the toolhead to a position that is out of limits. 650 20. This means each point is treated the same in relation to the tilt. From [bed_mesh] mesh_min = 10,10 mesh_max = 265,265 to [bed_mesh] mesh_min = 50,10 mesh_max = 265,265 Your issue is reporting a negative Y value. One may define a bed_mesh config section to enable move transformations that offset the z axis based on a mesh generated from probed points. bed_mesh cuts the bed in little segments and tries to compensate for bumpiness / unevenness location specific. Notifications You must be signed in to change notification settings; Bed_Mesh move out of range kills the calibrate process #5083. 0125, a range of 0. 5 then: your mesh_max must be (at most): 241 - 40. I assume this is all relative to the z-endstop switch, which I've kept. 1 until the nozzle touches a piece of paper on top of the build plate. This is run implictily at Klipper startup This document serves as a guide to performing bed leveling in Klipper. Nov 13, 2023 · Basic Information: Printer Model: Ender 3 v2 (modified) MCU / Printerboard: Manta M5p klippy. 5 and therefore out of range. SGr33n July 11, 2024, 11:58am 8. turning on the printer with the card inserted. Thanks Sineos! I already tried that values, they gives Move out of range. To prevent the MOOR error, the correct way is to adapt the starting points of the mesh in: [bed_mesh] mesh_min = 0, 0 mesh_max = 216, 179. 111 -4. In the following, we assume a Cartesian printer that follows the conventions of a Cartesian Coordinate System. As you have said ender clone, check your motions system, a loose v Jan 9, 2023 · Klipper: Bed Mesh – Simply Explained. Published Jan 9, 2023. Here is my config. mesh_min值的问题,该值未设置好导致 So, in the above example, since the printer uses a Z step distance of . You can display the probed mesh, the Mar 4, 2020 · The real issue is that your stepper_z position_min is set to -0. 15 F300 # Wait for bed to reach temperature M190 S{BED_TEMP} # Set and wait for nozzle to reach temperature M109 S{EXTRUDER_TEMP} [gcode_macro END_PRINT] gcode: # Turn off bed, extruder, and fan M140 S0 M104 S0 M106 S0 # Move nozzle away from print while Reddit formatting got you, but like this: [gcode_macro END_PRINT] gcode: # Turn off bed, extruder, and fan M140 S0 M104 S0 M106 S0 # Move nozzle away from print while retracting G91 G1 X-2 Y-2 E-3 F300 # Raise nozzle by 10mm G1 Z10 F3000 G90 # Disable steppers M84 Oct 2, 2023 · The X and Y Axis Klipper needs to know from its printer. 000] Feb 5, 2023 · G1 Z2. In rare situations this may result in confusing "Move out of range" errors after homing. It also needs to know where the origin (X=0 / Y=0) is. I will be happy to read your comments - maybe you have any idea how to fix the issue with incorrect Jul 11, 2024 · Basic Information: Printer Model: Enderwire MCU / Printerboard: BTT SKR E3 mini v2 Host / SBC klippy. V2. Some valleys are under 0 because you bed isn’t perfectly flat. 0 E30 ; Draw the second line G92 E0 ; Reset Extruder G1 Z2. 000] The x value 291mm is clearly out of the max range of 240mm. serial (on USART3 PB11/PB10), which is broken out on the 10 pin IDC. 3 F1500. Unknown command:"QUAD_GANTRY_LEVEL" Move out of range: -35. In this example, a radius larger than 76 would move the tool beyond the range of the printer. Jul 19, 2022 · I have an Ender 6 I have installed a Revo Hemera with BL-Touch and I am getting move out of range errors when the extruder goes near the back of the build plate. Again, they have not released the sources for this and the other components as required by the GPL license. cfg settings how far the X and Y axes can safely move without hitting the printer’s frame. Ok, mesh leveling 101. 000] klippy. Move out of range ?. Feb 21, 2022 · After the recommendation of @Ender5r , I have set up Klipper with my Ender 5Pro with CR-Touch and 4. 600 410. The printer starts at Y=0. The mesh_max value is calculated as: stepper_y. 4 R2 with Klicky Proble. My theory is that I hit some point in the bed that is low, and the mesh calibration is making the Z offset go negative. The mesh is for klipper to compensate not for you. Will warn (or optionally abort) if mesh_min or mesh_max could allow a move out of range during BED_MESH_CALIBRATE. SMART_PARK and LINE_PURGE come from the KAMP part but the bed_mesh is commented out. log Hello, looking for some help Im setting up klipper on my ender 3v2 i leveled the bed manual, and trying to create a mesh by running BED_MESH_CALIBRATE . 000 15. Need a little more bed mesh help. From Config reference for stepper position_max: Maximum valid distance (in mm) the user may command the stepper to move to. 701 [-3. 000 6. cfg to home toward the center of the print area. I have tried to get help from many youtubers but as usual they never answer help requests. however after it probes the first couple of points i get !! Move out of range: 245. Yeap, Thank you. M109 S{EXTRUDER} LINE_PURGE. # STM32F103 with a "28KiB bootloader" and serial (on USART1 PA10/PA9) communication. 1 Y20 Z0. 2 KB) Nead some help to solve this problem. If not called with the proper values, obscure things can happen. Klipper does NOT do that automatically, and you will need to adjust your mesh area appropriately. 4 Y20 Z0. log. Check Klipper out on discord, discourse, or Klipper3d. with no differences. I show a snippet of my [gcode_macro The Bed Mesh module may be used to compensate for bed surface irregularities to achieve a better first layer across the entire bed. 1 Y200. Been running Klipper on my delta for some time, smaller prints have been coming off the build plate fast and with very good quality. Now I built confidence in Klipper I started to try some taller prints, but they are consistently failing to go above Mar 22, 2024 · once the bed is warm I do these commands. 000 7. Problem solved. I followed the instructions for setting my X and Y offsets, however, I now have a problem with getting my bed mesh. Dec 30, 2021 · When performing the bed mesh calibrate process if you request a move that is out of range of the min/max in the config file, the entire calibrate process is killed and you have to start over. [bltouch] sensor_pin: ^PB1 # Move the nozzle near the bed G1 Z5 F3000 # Move the nozzle very close to the bed G1 Z0. The *_offset values must exactly match the actual hardware distance from your nozzle to the probe tip. by Matteo Parenti. If the results of the test show a range value that is greater than 25 microns (. Add the following to Z section e. Also refer to Understanding X and Y Axes Limits and Homing Reasons A direct movement command (G1 et al. 012 0. 9 MB) klippy. M84 X Y E ;Disable all steppers but Z. Updated cura and now ever time it goes to print the file "move out of range" error. The manual Z offset script will be activated to position the nozzle against the bed using the paper test. Use position_min: -3 . I have big problem with Z i don’t want put negative values on position_min MESH_MIN - See Klipper documentation for BED_MESH_CALIBRATE. 500 10. Bed Mesh also cannot compensate for mechanical and electrical issues. cfg (6. 249 -0. Ive been struggling with creating a bed mesh for my printer setup. Send: G1 Z0 Recv: !! Move out of range: 120. You have to start at leat at 24. I seem to get a Move out of range at a certain point in the calculation. Your bed mesh is falling below Z=0 and that’s why you get “out of range”. 20210819: In some cases, a G28 homing move may end in a position that is nominally outside the valid movement range. 531 you can work around this by setting the following to negative value. I am very new and any help would be appreciated, thank you in advance! (I have only included the first part of the Gcode as it "Home's" just fine so im guessing it is something directly after G92) Error: Move out of range: 197. If you’re having trouble creating a mesh f Move out of range Klipper My Gcode calls for my printer to move to 10. 000 -7. The min/max for the mesh is referencing the position of your probe ( See mesh document here) Your bltouch is at X -50, so with a maximum of 235 for your X axis, your maximum probe position is 235-50=185. but stuck here On several tests the results yield the same Move out of range: 57. Aug 12, 2022 · With start at 10, it is, regarding you start at -20, at 10mm left out of the bed (all values in X direction). Checks the [bed_mesh] config and optionally supplied parameters. # Also, since it is using the GD32F103, please select Disable SWD at startup. Then likely you made a mistake. Sep 19, 2021 · When starting a print I often get this error: Move out of range: 250. Aug 20, 2020 · Printer: Anycubic Kossel Linear Plus, factory probe, bed, extruderm heater and other mechanical elements. If i press Bed_Mesh_Calibrate, the toolhead pic… Jan 1, 2024 · Creality Sonic Pad and Alternatives Knowledge Base. 5. Dec 30, 2021 · Klipper3d / klipper Public. SMART_PARK. cfg. 6 MB) Describe your issue: I upgraded my ender 3 to run klipper roughly a year ago and i have only recently noticed (by printing larger objects) that my printer isn’t printing in the center of the bed. 000 227. Jul 19, 2022 · Will try these settings and let you know thanks. log file (use zip to compress it, if too big). RaoulFabisch closed this as completed on Sep 19, 2021. Feb 20, 2024 · Hi everybody, I’m wondering what the best strategy in using the capabilities of Klipper’s bed leveling tools might be. 000 [0. Fill out above information and in all cases attach your klippy. It should be noted that software based correction will not achieve perfect results, it can only approximate the shape of the bed. In bed mesh however you’re asking it to go to 205 which is out of range. Feb 13, 2023 · Move out of range: X Y Z [E] Background A movement beyond the physical limits was attempted. Make sure though your probe is indeed on the bed, and you don’t crash just off it. For example, if the [bed_mesh] section is set to 9×9 for a 300mm² bed, then it will compute for a 100mm² first layer surface a 3×3 mesh. 000. I used the following commands: G28. The Bed Mesh module may be used to compensate for bed surface irregularties to achieve a better first layer across the entire bed. To perform the basic probe, make sure the config has a [delta_calibrate] section defined and then run the tool: The Bed Mesh module may be used to compensate for bed surface irregularties to achieve a better first layer across the entire bed. 0 F3000 ; Move Z Axis up little to prevent scratching of Heat Bed G1 X0. But it wouldn't retract and the BLTouch would stay fired. I had set mine to almost minus one millimeter. position_max + probe. 190 will be the max position your probe can reach on the x axis. 0 fade Jul 19, 2022 · 5. 000 2. This is also the reason Aug 16, 2023 · why is the bed mesh calling for a y -7 move that causes my printer to abort doing the bed mesh with beacon 😬 Move out of range: 50. For example, SCREWS_TILT_CALCULATE MAX_DEVIATION=0. 5) But this issue is because your position_min is 2. 5 and you are trying to move to X=0, which is less than 2. What i mean by this is that in my slicer (i am using orca slicer 1. Negative position is not dangerous as long as you don’t try deliberate to move your Z under 0 but it’s necessary as a buffer for mesh. This origin is the beginning of the usable printer bed. 3 F5000. I would be so grateful for some advice. 00. 913 [62. 000 238. move out of range:移动超出距离. In addition, you can limit the scale to the min/max values of the profile with the toggle switch. g. The issue is when I set the mesh_max value to anything more than 195mm (235-40) the mesh probe process stops before it gets to the last point Nov 19, 2019 · Based on the info here, Klipper: G-code commands - Mesh Bed Leveling I would expect Klipper to adjust for the differences seen in the visualization above, but the initial layers of my prints are very squished on the right and rear of bed (right and rear of image) and not squished on the left and front of the bed (left and front of image) which Move out of range after bed mesh complete Very new to Klipper and trying to get it working on the same tablet I have running Octoprint connected to my Ender 3 V2. (2) Go to slicer setting and replace the old bed mesh gcode the following command. You may start with mesh_min 45,15 Aug 25, 2023 · Move out of range: 237. 775] Help appreciated. y_offset. Flash this firmware by copying "out/klipper. Again, they are violating the OSS license and making money off the Your X bed mesh minimum value needs changing to take into account the probe position offset. I’ll show here what I currently do and try to explain my thoughts, why I do it this way. 408mm) it hit the limit you gave it and stopped the print. log (46. I can get the printer to move in all axis and even build a bed mesh with the CR-Touch. Printer keeps showing “move out of range”. You can make your z limit a lower number (further negative), but doing a little leveling will probably make your life easier. Jul 14, 2022 · Klipper Move out of range when doing Bed_Mesh_Calibrate. Help!! Klipper bed mesh keep saying Move out of range after performing bed leveling upvotes The manual probing method will move the head near the bed and then wait for the user to follow the steps described at "the paper test" to determine the actual distance between the nozzle and bed at the given location. The “move out of range -10. klippy. Set up your bl touch on Klipper. See what people are saying on Problems with offset and mesh_min/max. Hi after installing Klipper on my Ender 3 S1 (with S1 Pro extruder) I did a mesh calibration and saved it, then printed a Benchy which looked fine. Attach the file per the instructions linked by the bot. 310. Be sure to check our “Knowledge Base” Category first. 200 -0. Jan 24, 2024 · Clear any stored bed meshes with BED_MESH_CLEAR; Run Z_ENDSTOP_CALIBRATE (V0, Trident, V2) or PROBE_CALIBRATE (Switchwire) Slowly move the nozzle toward the bed by using TESTZ Z=-1 until the nozzle is relatively close to the bed, and then stepping down with TESTZ Z=-0. 7. 0 samples = 3 samples_result = median sample_retract_dist = 3. Doing QGL, Probe_Calibrate or Probe_Accuracy, all OK. 500 5. cfg] # This file contains pin mappings for the stock Sovol SV06. 01 can be added to the custom start gcode of the slicer before the mesh is loaded. 99, so when your nozzle tried to go somewhere near your low corner (which is at -1. Jun 17, 2022 · klipper配置klicky时错误信息及解决办法. If the printer is commanded to a position X0 Y0 Z10 during a print, then the goal is for the printer's nozzle to be exactly 10mm from the printer's bed. 000] Recv: !! Move out of range: 291. 5 = 200. 000 38. Position the toolhead far from the bed, issue a G28 (or PROBE if not using probe:z_virtual_endstop), wait until the toolhead starts to move down, and stop the movement by very gently touching the pin with your nail. 000] NOTE: I do not use the BLTouch to home the Z. . Now when I slice and print an ADXL345 bed adapter I am getting the following error: Move out of range: 20. For your [stepper_z] you need to temporarily set your position_min to a sane negative value to stretch the Out of range checks. 0 F3000 ; Move Z Axis up little … Jul 10, 2024 · To prevent the MOOR error, the correct way is to adapt the starting points of the mesh in: [bed_mesh] mesh_min = 0, 0 mesh_max = 216, 179. This includes the name, size, min and max values, as well as the variance. 000 with the bed mesh. cfg: On this area, a new set of points is computed to get at least the same precision (or better) as the original [bed_mesh] section. You may have to do it twice, since the select "Enable extra low-level configuration options" and select. -樂懿. I thought I had the config file correct. cfg and the gcode file attached here have an extra txt extension added (for the github to accept them). org Members Online. Every time I try to print I get a move The MAX_DEVIATION parameter is useful when a saved bed mesh is used, to ensure that the bed level has not drifted too far from where it was when the mesh was created. 000] The mesh_min, and mesh_max have to take into account the offsets of the probe. You can limit the scale by moving the sliders down or up. * (Cura slicer plugin) To make the macro to work in Cura slicer, you need to install the post process plugin click here to download (based Oct 8, 2023 · Printer Model: anycubic mega s. Feb 18, 2022 · I have checked the probe accuracy and it seem to be fine. txt. : r/klippers. It is saying out of range, it is not out of range in my config nor is it out of the physical range of the printer, I don't know what is going on, appreciate any help So, in the above example, since the printer uses a Z step distance of . M-Maika July 14, 2022, 8:35am 3. Creality Sonic Pad Update Since July 11, 2023, Creality seems to have released a firmware with a newer Klipper version. klipper. 006 samples_tolerance_retries = 3 [bed_mesh] speed = 240 horizontal_move_z = 10 mesh_min = 20, 20 mesh_max = 290, 290 probe_count = 5,5 fade_start = 1. Jul 10, 2024 · Then it is very wrong to do so. # To use this config, during "make menuconfig" select the. 0 samples_tolerance = 0. This is separate from the bed size. I've tried a few different iterations of mesh settings, min/max, probe count, etc. E. Lower the mesh_max and you should be fine. 000] In all my other printer during calibration of Z offset there is a override of limits I am scratching my head fonding where I am wrong without success, any idea? But, I just can't figure this out. I’d like to invite you to add your experience and insights in finding the best practice in homing, z-tilt an bed-meshing as mentioned above. It need to be high enough resolution that the curve of the bed is represented, not made into straight lines, otherwise you'll be high in some places and low in others. 000] Gcode: Printer. 000 10. Sep 1, 2022 · bed_tilt treats your entire bed as one plane and tries to compensate for a tilt. 727 285. 000 -0. Jan 22, 2022 · Move out of range: 100. It's important to understand the goal of bed leveling. Once you've got the firmware up and running, learn how to work the Jun 3, 2024 · Setup guide. log (1. There is Feb 3, 2022 · [bed_mesh] speed = 100 horizontal_move_z = 5 mesh_min = 5,5 mesh_max = 220,220 probe_count = 5,5 algorithm = bicubic You have to calculate the bl_touch offset into your bed_mesh points. When using a probe to home the z-axis, it is recommended to define a safe_z_home section in printer. 000] it tries to go to these locations Move out of range: 20. Pasting your printer. 000] Jan 9, 2020 · Recv: !! Move out of range: -5. Jan 18, 2023 · If I do the commands you suggest it works as expected, but the if the bed_mesh is active the opposite happens G28 homes and sets Z at 207. 0 z_offset = -10 speed = 10. MCU / Printerboard: klippy (6). 800 41. Why is the bed mesh levelling trying to go there? klippy. Bed level support¶ [bed_mesh]¶ Mesh Bed Leveling. 171 [0. [include mainsail. 1 20. If I issue BED_MESH_PROFILE LOAD=default and then issue the same commands the Z is set to 207. Only once that has been successfully configured and confirmed should you then take a look at your mesh_max . Jan 21, 2023 · M140 S0 ;Turn-off bed. Your stepper_x position_min (and position_endstop) is 2. This means one point can go up, the next down. Sineos July 11, 2024, 1:08pm 9. Once you've got the firmware up and running, learn how to work the Klipper bed mesh compensation. BED_MESH_CLEAR. mesh_radius: 75 Required The radius of the probed mesh in mm, relative to the mesh_origin. 4 Y200. 0) if i The Bed Mesh module may be used to compensate for bed surface irregularities to achieve a better first layer across the entire bed. bed mesh or gcode offsets) pushed the movement target beyond the physical limits Potential solutions How In the "Current Mesh" panel you get some values of the currently loaded mesh. 0 ; Move to side a little G1 X0. Jan 21, 2023 · Mesh is just a map of hills and valleys. 000 9. [probe] pin = EBBCan: PB8 x_offset = 0 y_offset = 25. log klippy. After you've calibrated your probe and set the z_offset value, remove the position_min or set it to 0 like you have now. (Also you should have a space in there between position_min: and 2. : [gcode_macro _TOOLHEAD_PARK_PAUSE_CANCEL] Jul 19, 2022 · Else try these settings: V2. I decided to increase the area for "bed mesh" and indicated the points 100,100 and -100,100 in the config. When you start at 5,5 and the bl_touch offset is 40,10 then the test position is 5-40=-35 for x and 5-10=-5 for y. 016 [4. printer. Note that the probe's offsets limit the size of the mesh radius. If i press Bed_Mesh_Calibrate, the toolhead pic…. log (5. Thank you. 000] Move out of range: 2. bb iw ya as bx pg qb ih lk rq